- 2 xSyringe 2g
- 10 x Applicator Tips
- 1 x Instruction Manual
Direction to Use
Preparation:
- Ensure proper isolation of the operating site for effective moisture control.
- Thoroughly clean the surfaces to be sealed using a rotating brush or cleaning paste free of fluorides.
- Etch the enamel with Actino 37% etching gel according to the condition of the enamel, then spray and dry. The etched enamel should appear opaque and matt-white.
Application:
- Remove the protective cap from the syringe and attach a new cannula.
- Apply Prevest Denpro PF Seal Pit and Fissure Sealant from the margin into the fissure or cavity.
- Allow the sealant to penetrate for 15 ・20 seconds, ensuring complete coverage.
- Use the fine cannula to remove any air bubbles.
Light-curing:
- Polymerize the sealant for 40 seconds per surface using a suitable polymerization device.
- Ensure the light output is at least 500mW/cm2 on halogen devices or 300 mW/cm2 on LED devices for optimal curing.
Finishing:
- Re-seal any undercuts and remove excess material cautiously using a finishing diamond.
- Polish the sealed area if necessary with a rubber polisher.
Additional Treatment:
- Apply fluoride varnish on the treated and neighboring teeth to provide additional protection.
Warranty
- Warranty is not applicable for this product.