SDI GS 80 – 1/2 Spill – 50 Capsules
Optimal handling characteristicsGS-80?s consistent mix, ease of loading, placement in preparations, condensability, burnishability, quality of interproximal contact, carvability, and setting characteristics ensure the fi nal restorations meet the needs of the operator.High compressive strengthGS-80?s high compressive strength minimizes the risk of fracturing the restoration.(1) High compressive strength ensures a tough and durable long lasting restoration.Positive dimensional changeGS-80?s positive dimensional change ensures excellent sealing qualities at the margins.(1) Negative values can contribute to post operative sensitivityCapsule systemThe SDI capsule system is designed to give consistent and accurate mixes every mix.Greater choice of setting times and larger choice of capsule sizesThe working and setting times allow large restorations to be condensed and carved without diffi culty.
Features
Optimal handling characteristics
GS-80?s consistent mix, ease of loading, placement in preparations, condensability, burnishability, quality of interproximal contact, carvability, and setting characteristics ensure the fi nal restorations meet the needs of the operator.
High compressive strength
GS-80?s high compressive strength minimizes the risk of fracturing the restoration.(1) High compressive strength ensures a tough and durable long lasting restoration.
Positive dimensional change
GS-80?s positive dimensional change ensures excellent sealing qualities at the margins.(1) Negative values can contribute to post operative sensitivity
Capsule system
The SDI capsule system is designed to give consistent and accurate mixes every mix.
Greater choice of setting times and larger choice of capsule sizes
The working and setting times allow large restorations to be condensed and carved without diffi culty.
Description
The technically advanced, non-gamma 2 admix amalgam at an affordable price. GS-80?s high strength ensures longevity and patient satisfaction. The alloy to mercury ratio varies between 1/0.85 and 1/0.94 depending on the size and setting time, i.e. 45.9% to 48.5% by weight mercury. The compressive strength of GS-80 at 24 hours is 510 MPa, and the dimensional change during hardening is .02%.
Key Specifications
COMPOSITION:
- Alloy Particle: Spherical and Lathe Cut
- Compressive strength -1 hour: 225MPa (32,625psi)
- Compressive strength -24 hours: 510MPa (73,950psi)
- Diametral tensile strength -1 hour: 22MPa (3,190psi)
- Diametral tensile strength -24 hours: 54MPa (7,830psi)
- Static creep -7 days: 0.1%
- Dimensional change -24 hours: µm/cm
- Jar of 50 capsules – one spill 200mg alloy
- Jar of 50 capsules – one spill 400mg alloy
Packaging
SDI GS 80 – 1/2 Spill – 50 Capsules:
SDI GS 80 – 1 Spill – 50 Capsules:
Direction to Use
INSTRUCTIONS:
1. Select the appropriate size capsule according to colour coding
2. With the capsule inverted, SLOWLY press the plunger end of the capsule against a flat surface until the flange of the plunger is flush with the capsule body
THIS IS MOST IMPORTANT. Initially, resistance will be felt, then suddenly released as the plunger pierces a diaphragm allowing the mercury to enter the mixing chamber
3. Slightly spread the amalgamator clips and carefully insert the capsule. Ensure that the capsule is securely anchored between the clips
4. Select the appropriate mixing time from the suggested mixing times A range of mixing times is given to accommodate mixing variations that can occur due to machine type, age and line voltage. Correctly triturated amalgam will form into a bright homogeneous plastic mass. A hot, shiny, sticky mass indicates over trituration whilst a dull, dry or powdery mass is under triturated
5. After trituration has been completed, carefully remove the capsule from the clip
6. Tap the base end of the capsule sharply on the bench to ensure that the mixed amalgam is located in the base of the capsule
7. Separate the base from the body and remove the prepared amalgam from the capsule. If the small separating diaphragm has come away from the capsule wall during activation and mixing, it will separate cleanly from the amalgam
8. CONDENSATION: Moisture contamination: If moisture has introduced into the amalgam before it has set, properties such as strength and corrosion resistance may be affected adversely. If the alloy contains zinc, such contamination may result in an excessive expansion (delayed expansion). Whenever it is possible, use a dry field. Insertion of the amalgam should commence immediately after trituration. It is not necessary to express mercury prior to insertion. Traditional condensation techniques are recommended. Pack angles and undercuts with a small-faced plugger, using sufficient pressure to ensure good adaptation. Build the restoration with additional portions until cavity is slightly over filled. Remove any mercury rich amalgam from the surface, that may develop during condensation
9. FINISHING: Trimming and carving can be commenced immediately condensation has been completed. Light burnishing can be used to advantage and if the restoration is polished, this procedure should be carried out after 24 hours. Avoid overheating by ensuring adequate water cooling and low speed polishing.
1. We offer Worldwide Shipping by Courier via Air or Sea mode.
2. Product will be dispatched within 5-7 working days.
3. Delivery will take a maximum of 7-15 days, based on the shipping option you choose.
4. Kindly check customs restrictions and rules in your country for specific products, mostly 99% shipments are cleared and delivered smoothly.
5. For Bulk inquiries or customized manufacturing please contact us.
Product Enquiry
- Medical Supplies
- Urology, Ostomy & Incontinence
- Gynecology & Infant Care
- Respiratory Care Products
- Nursing Supplies/Patient Care
- Health & Nutrition
- Wound Care & Dressings
- Medical Equipment
- Ophthalmic Supplies
- Diagnostic Instruments
- Diagnostic & Imaging Supplies
- Orthopaedic & Trauma
- Cardio Thoracic Surgery
- Dental Products
- Prosthodontics
- Rative Next
- Dental Equipment
- Restoratives
- Patient Education
- Dental Furniture
- Offers
- Clinical Problem Solvers
- Dental Models
- Dental Consumables
- Orthodontics
- Oral Surgery
- Student Section
- Periodontics
- Cosmetic Dentistry
- General Dentistry
- Sterilization
- Endodontics
- Kits
- Medical Supplies
- Equipments
- Laboratory
- Implantology
- Instruments
- Basic Dental Products
- Paedodontics
- Preventives
- Corona Safety
- Lab Supplies
- Lab Equipment
- Leak Test Apparatus
- Titrimeters
- Distilling Apparatus
- Magnifiers
- Microscope Accessories
- Water Bath
- Shakers & Rotators
- Photo Colorimeter
- Laboratory Stirrer
- Disintegration Test Apparatus
- Dissolution Test Apparatus
- Laboratory Mixers
- Lab Junction Tonometer, LJ-2501
- Melting Point Apparatus
- Centrifuges
- Spectrophotometer
- Microscopes
- Lab Equipment
- Dialysis Supplies
- Mobility Aids
- Point of Care Testing
- Cath Lab Products
- Gloves
- Anatomical Models
- Rehabilitation
- Medical Accessories
- Cleaning and Waste Management
- Hearing Aids
- Medical Clothing
- Medical Simulators
- Respiratory & Anaesthesia Supplies
- Hospital Apparel, Linen and Personal Protection
- Sterilization, Antiseptics & Disinfectants
- IV, Infusion & Transfusion
- Surgical Instruments
- Medical Equipments
- Surgical Supplies
- Braces, Splints & Supports
- Medical Instruments
- Surgical Sutures
- Body Weight Machine
- Needles & Syringes
- Dental Supplies
- Veterinary
- Agro Chemicals
Related Products
Straight spatula, The handle is arabesquitic, Easy handling, Flat smooth fore-end of the spatula is better for mixing the medicine well , Autoclavable at 120°C for repeated use, Blue, 1 Piece
Strong one-piece construction. Provides complete view for anterior and posterior teeth, Made of durable clear medical grade plastic , Compatible with the cold sterilization or the autoclave (<121°C), The smooth surface makes it very comfortable for the patient. Protects the sensitive gums during teeth whitening treatment. Available in adult size or child size, Opens the oral cavity widely, without any pain
Strong one-piece construction. Provides complete view for anterior and posterior teeth, Made of durable clear medical grade plastic , Compatible with the cold sterilization or the autoclave (<121°C), The smooth surface makes it very comfortable for the patient. Protects the sensitive gums during teeth whitening treatment. Available in adult size or child size, Opens the oral cavity widely, without any pain