GC Fuji 1 Capsule Box Of 50

No primer or adhesive is required, Simple cementation technique, Cariostatic activity, Easy to mix and handle, Restorations’ seat is better; has fewer problems, Non-precious and precious metal to tooth structure, Minimizes microleakage, Coefficient of thermal expansion is similar to tooth structure, Reduced microleakage, Less chance of washouts and sensitivity developing, Faster “Snap Set” with more working time, Greater longevity and restoration integrity

This product is currently out of stock and unavailable.

  ... people are viewing this right now

Features

Bonds in a Wet Field

  • No primer or adhesive is required
  • Simple cementation technique

Sustained Fluoride Release

  • Cariostatic activity

Smooth, Creamy Consistency

  • Easy to mix and handle

Low Film Thickness

  • Restorations’ seat is better; has fewer problems

Strong Direct Bond

  • Non-precious and precious metal to tooth structure

Superior Marginal Seal

  • Minimizes microleakage
  • Coefficient of thermal expansion is similar to tooth structure

Low Solubility After Set (.06%)

  • Reduced microleakage
  • Less chance of washouts and sensitivity developing
  • Faster “Snap Set” with more working time

Strong Bonding, Compressive and Tensile Strengths

  • Greater longevity and restoration integrity
  • Description

    Radiopaque Glass Ionomer Luting Cement in Capsule
    Chemically cured strontium based glass ionomer cement ideal for basic luting of metal based restorations in the convenient capsule delivery.

    Composition

    polybasic carboxylic acid**-10-20%

    Indications

    • Cementation of metal-based inlays, onlays, crowns, bridges and posts
    • Cementation of high strength (zirconia based) all ceramic crowns and bridges

    Key Specifications

    TECHNICAL DATA:

    • Powder / Liquid ratio (g/g) :0.33/0.18
    • Mixing time (sec.):10 secs
    • Working time (min., sec.) (at 23 °C) (from start of mixing):2 mins 15secs
    • Final finishing commencing time (after seating the restoration):4 mins 30 secs

    CONTRAINDICATIONS

    • Pulp capping
    • In rare cases the product may cause sensitivity in some people. If any such reactions are experienced, discontinue the use of the product and refer to a physician.

    STORAGE

    Recommended for optimal performance, store in a cool and dark place (4-25°C) (39.2-77.0°F).

    Shelf life : 3 years from date of manufacture

    Packaging

    Gc Fuji 1 Capsule Box Of 50:

    • Box of 50 Capsules

    Gc Fuji 1 Capsule Box Of 30:

    • Box of 30 Capsules
    • Direction to Use

      1. TOOTH PREPARATION

      a) Prepare tooth in usual manner. For pulp capping, use calcium hydroxide

      b) Clean the prepared teeth with pumice and water

      c) Rinse thoroughly with water. Remove excess moisture by blotting with a cotton pellet or gently blowing with an oil-free air

      DO NOT DESICCATE. Prepared surfaces should appear moist (glistening)

      2. RESTORATION PREPARATION

      Make sure that the restoration is pretreated and handled according to the manufacturer?s instructions

      3. CAPSULE ACTIVATION AND MIXING

      a) Before activation, shake the capsule or tap its side on a hard surface to loosen the powder

      b) To activate the capsule push the plunger until it is flush with the main body

      c) Immediately place the capsule into a GC CAPSULE APPLIER and click the lever once

      The capsule is now activated

      Note : The capsule should be activated just before mixing and used immediately

      d) Immediately remove the capsule and set it into a mixer (or an amalgamator) and mix for 10 seconds (4,000 RPM)

      Note: When using a rotational mixing device, it is recommended not to use the centrifuge option

      4. DISPENSING

      a) Immediately remove the mixed capsule from the mixer and load it into the GC CAPSULE APPLIER

      b) Make two clicks to prime the capsule

      To adjust the direction of the nozzle, hold the applier with the capsule towards you and turn the capsule body

      c) Extrude directly into the restoration

      d) To remove the used capsule, push the applier release button. Twist the capsule and pull upwards

      5. CEMENTATION

      a) Coat the internal surface of the restoration with sufficient cement and seat immediately. The working time is 2 minutes 15 seconds from start of mixing at 23°C (73.4°F). Higher temperatures will shorten working time

      b) Maintain moderate pressure

      c) Start removing excess cement when the excess cement feels rubbery. d) Finishing can be started 4 minutes 30 seconds after seating the restoration.

1. We offer Worldwide Shipping by Courier via Air or Sea mode.
2. Product will be dispatched within 5-7 working days.
3. Delivery will take a maximum of 7-15 days, based on the shipping option you choose.
4. Kindly check customs restrictions and rules in your country for specific products, mostly 99% shipments are cleared and delivered smoothly.
5. For Bulk inquiries or customized manufacturing please contact us.

Product Enquiry

Categories
My Cart
Wishlist
Recently Viewed
Categories