Waldent Electric Pulp Tester

Original price was: $ 162.50.Current price is: $ 43.28.

Preset speed mode (high-mid-low speed), Gentle, pulsed stimulus begins to increase at a rate of high -mid-low speed. Specifically designed for patient comfort (If patient indicates perception, simply release the button. The stimulus stopped immediately, but the numbers remain frozen on the screen for about 3mins, Convenient to operate.0-40, the patient feels mild pain, means the tooth , is vital,  40-80, with above mentioned reaction , tooth is non vital. >80, no above mentioned reaction dead tooth nerve.

QuantityPrice
2 - 5 $ 42.85
6 - 10 $ 42.41
11 - 20 $ 41.55
21 - 50 $ 41.12
51 + $ 40.25
Bulk Inquiry
  ... people are viewing this right now

Features

  • Preset speed mode (high-mid-low speed)
  • Gentle, pulsed stimulus begins to increase at a rate of high -mid-low speed.
  • Specifically designed for patient comfort (If patient indicates perception, simply release the button. The stimulus stopped immediately, but the numbers remain frozen on the screen for about 3mins
  • Convenient to operate.
  • Peak of stimulus current reaction numerical value.

    •  0-40, the patient feels mild pain, means the tooth is vital
    •  40-80, with above mentioned reaction tooth is non vital.
    • >80, no above mentioned reaction dead tooth nerve.
    • Description

      Waldent Electric Pulp Tester It is a device to examine the vitality of dental pulp using the electric stimulation.The currrent used to stimulate the intradental nerves therefore creating a response. Studies were accompanied to measure the responses subjects by stimulating over the sensory threshold to determine the vitality of tooth. It works in an efficient way. An Electric current can be applied to the tooth in order to generate an action potential in the type A delta fibres within pulp ; this elicits a response. This test is conducted by applying a medium like toothpaste,on dried tooth. One end is placed on the tooth surface near the pulp horn and the other end is placed on the lip. 

      Key Specifications

      • Battery Operated
      • Output Voltage: 9.0V DC
      • Output Current: 9.0 mA

      MAINTENANCE:

      • Should not be dismantled.
      • Standard disinfection procedure should be used for disinfection,should be stored in a proper way in the original packaging box
      • Please use the original charger, any other charger may result in the damage of the battery and the controlled electric circuit: even the machine will be greatly damaged.
      • The unit should be scrubbed by pure water or ethanol and follow the standard disinfection procedure to disinfect the materials.
      • The pulp tester should be placed in the original packaging box in a dry and clean cupboard.
      • Do not open the Power Unit, except to change the battery. There are no user-serviceable parts inside.Internal repairs are to be made only by authorized Parkell personnel, by returning the unit to the service address at the end of these instructions 
      • Handle the power unit with care
      • Battery should be removed if unit is to be stored unused for more than 30 days
      • To prolong battery life, the device automatically turns off after 14 seconds of inactivity
      • When the battery capacity is low, the Left and Right digital display digits will flash alternatively while the unit is activated. Replace the battery as explained in the section ?Changing the Battery?
      • If a Tooth Probe becomes loose in the mount of the Power Unit, it may be tightened by carefully inserting a flat screwdriver blade into the split metal base of the probe and gently expanding the sides apart with a twist of the tool.
      • Discard and replace any Tooth Probe if the metal or the insulation becomes damaged during use.

      Packaging

    • 2 x Test Electrode
    • 1 x Cable Socket
    • 1 x Light Indicator
    • 1 x Battery
    • Direction of use

      1. Make the test wire link with the cable socket of the unit, afterwards insert the stainless steel hook and the test electrode into the interface of the unit.
      2. Strictly separate the tooth which will be measured from the saliva, blow the surface of the tooth until it is dry, so as to forbid the stimulation electric current to conduct from the gingiva or else there will appear a false stimulus current.
      3. Hang the stainless steel hook on any side of the mouth, then select different speed mode.
      4. Paste a spot of conducting glue or toothpaste on the contact interface (1/3 slide side) between test electrode and selected tooth. Then press the power switch.
      5. When the patient slightly feels toothache or anesthesia, You should take the test electrode away from the tooth and observe the figure on the screen in order to record it, this figure is the tooth’s stimulation current reaction number.

       

      FAQs

      Q.How does an electric pulp tester work?
      A.The EPT measures the vitality of the dental pulp indirectly, by sending a gradually increasing electrical current through the tooth to stimulate a sensory response. Every tooth is innervated by nerve fibers arising from the trigeminal (V) nerve nucleus.

      Q.How do you test an electric pulp?
      A.Such tests are conducted by applying a conducting medium (e.g. toothpaste) on a dried tooth and placing the probe tip of an electric pulp tester on the surface of the tooth closest to the pulp horn(s).

      Q.What is the difference between pulp sensibility tests and pulp vitality tests?
      A.Pulp sensibility tests (thermal and electric) have been used to indirectly determine the state of pulpal health by assessing the condition of the dental pulp nerves. Pulp vitality, on the other hand, is the direct assessment of pulp blood flow.

       

      Warranty

      • Manufacturer/Importer warranty of 6 months as applicable for this product.
      • Service and Warranty are handled by the manufacturer/importer directly for this product
      • Divne Medicare will not be liable to replace the Products and the liability to replace any such Product is that of the Manufacturer/Importer
      • Divne Medicare and the Buyer acknowledge that the Products purchased/usedare a subject matter of original Manufacturer/Importer?s warranties only
      • Any or all claims in relation to returns and replacement shall be made to the concerned Manufacturer/Importer only and Divne Medicare may assist the customer in registering a request to get the Product replaced or serviced.
      • The Buyer acknowledges that the Products once sold will not be exchanged or taken back unless the seal of the package or the Product is intact or not altered in any manner or is not tampered as the case may be.

      1. We offer Worldwide Shipping by Courier via Air or Sea mode.
      2. Product will be dispatched within 5-7 working days.
      3. Delivery will take a maximum of 7-15 days, based on the shipping option you choose.
      4. Kindly check customs restrictions and rules in your country for specific products, mostly 99% shipments are cleared and delivered smoothly.
      5. For Bulk inquiries or customized manufacturing please contact us.

      Product Enquiry