Waldent Premium Plus Airotor Super Torque (W-122)

Original price was: $ 142.50.Current price is: $ 45.94. $ 45.48

Premium Plus Airotor with scratch resistant stainless steel body.

QuantityPrice
2 - 5 $ 45.48
6 - 10 $ 45.02
11 - 20 $ 44.10
21 - 50 $ 43.64
51 + $ 42.72
Bulk Inquiry
  ... people are viewing this right now

Features

WATER SPRAY :

  • Double Water Spray Jets used for cooling.
  • The ultra-precise nebulization cools the bur and the dental material as efficiently as possible. 
  • A water jet helps evacuate debris from the work field.

 

PUSH-BUTTON SYSTEM :

  • Push-button cartridge to change bur, easy and convenient.

 

BORDON 2-HOLE :

  • Bordon 2-Hole connection for better Compatability.
  • Usually, the standard in India where the large hole is for air and the smaller hole is for water. 

 

ERGONOMIC DESIGN :

  • High-grade material with a stylish design.
  • Push-button cartridge to change bur easy and convenient.

 

BEARING : 

  • Ceramic ball bearing in the handpiece with light ensures vibration-free and quiet operation and also provides long service life.
  • They are more corrosion-resistant, harder, and last longer in everyday use.

Description

Waldent Premium Plus Airotor Super Torque is a specially designed airotor under Premium Plus Range with super torque speed. Waldent Premium Plus Airotor Super Torque is designed to facilitate user-comfortability for the professional and a significant reduction in procedural times for their patients. The specially designed head size with a better grip contributes to a specialized level of visibility and maneuverability for users. With the innovative Economical technique, the exclusive design & those hard to reach and hard to see places are more easily accessible, thus streamlining and shortening procedures, making it possible to achieve results with greater accuracy and precision. 

INDICATION:

Used for cavity preparation, removal of tooth structure and margin creation.

ADVANTAGES:

  • Integral stainless steel body with resistance to scratch.
  • Lightweight.
  • Integrated machining & forming head.
  • Strong power.
  • Low Noise with enhanced cutting efficiency.

Key Specifications

TECHNICAL SPECIFICATIONS:

 Rotation speed
More than 3,50,000rpm
 Working air pressure 
0.28Mpa-0.30Mpa
Material
High grade stainless steel
Atomized Water
Pressure
0.3-0.35Mpa
Working Water
Pressure
0.2-0.23Mpa
 Bur applicable size
 1.590-1.600 mm ISO standarised burs
 Head standard
 Supertorque
 Chuck bur
 Push Button
 Bearing 
 Ceramic Bearing
 Available connection 
 2 holes 
 Noise 
 Less than 65 dB
  • Head Size: ∅12mm x H14mm
  • Total Length: 12.5cm

STERILIZATION:

  • Brush off excess dirt & wipe clean with an alcohol-soaked cloth.
  • Autoclave for 20 mins at 121°C or 15 mins at 135°C.

Packaging

  • 1 x Airotor Handpiece
  • 1 x Key
  • Instruction Manual

For Waldent Premium Plus Airotor Cartridge: Click here to buy the Airotor Cartridge

Direction to Use

Pre-Operative Inspection:

  • Before use, visually inspect the airotor for any damage or irregularities.
  • Check the cleanliness and sterility of the instrument.

Hand Hygiene:

  • Ensure that you have washed and sanitized your hands thoroughly before handling the airotor.

Connecting to Air Supply:

  • Connect the airotor to the dental unit’s air supply.
  • Confirm that the air pressure settings are within the recommended range (0.18~0.25 MPa).

Loading Burs:

  • Select the appropriate bur for the intended dental procedure.

Patient Preparation:

  • Communicate with the patient, explaining the procedure and addressing any concerns.
  • Administer local anesthesia if necessary.

Operation:

  • Hold the airotor with a comfortable grip, utilizing the specially designed head for enhanced visibility.
  • Start the airotor and carefully approach the treatment area.
  • Use light, controlled pressure to perform cavity preparation, tooth structure removal, or margin creation.

Post-Operative Care:

  • After the procedure, turn off the airotor.
  • Disconnect the airotor from the air supply.

Cleaning and Sterilization:

  • Brush off excess dirt from the airotor head.
  • Wipe it clean with an alcohol-soaked cloth.
  • Insert the handpiece into a sterilization pouch, seal it, and autoclave following the specified guidelines (20 minutes at 121°C or 15 minutes at 135°C).

1. We offer Worldwide Shipping by Courier via Air or Sea mode.
2. Product will be dispatched within 5-7 working days.
3. Delivery will take a maximum of 7-15 days, based on the shipping option you choose.
4. Kindly check customs restrictions and rules in your country for specific products, mostly 99% shipments are cleared and delivered smoothly.
5. For Bulk inquiries or customized manufacturing please contact us.

Product Enquiry

Categories
My Cart
Wishlist
Recently Viewed
Categories

Wait! Don't Miss Out on Your Perfect Cart 🛒💫

We noticed you left something amazing in your cart! 🎁✨ Don't let it slip away – just one step away from checkout bliss! 🛍️ 💥 Save 10% off your entire purchase today – use code SAVE10 at checkout! 💥 Hurry back and complete your order now! Time's running out! ⏳🏃‍♂️