Features

  • Fine Epoxy powder-coated matte finish
  • Inner chamber made of rust-proof stainless steel with a bright mirror finish
  • 12 stainless steel autoclavable trays
  • UV light source for effective germicidal irradiation
  • Magnetic gasket on the door for a tight seal
  • Micro door switch for UV source cutoff during door opening
  • Corrosion-resistant construction for durability and longevity.
  • Ultraviolet germicidal irradiation (UVGI) technology
  • High-quality ultraviolet light for efficient functioning
  • Description

    Waldent Wal-Cab UV Chamber 12 Trays is a state-of-the-art device designed to maintain the sterility of instruments after they have been sterilized by an autoclave or sterilizer. Utilizing ultraviolet germicidal irradiation (UVGI) technology, this chamber effectively eliminates any remaining bacteria, viruses, or other pathogens that may have survived the initial sterilization process. With its epoxy-coated exterior, the UV chamber ensures durability and longevity. It features a spacious interior with a 12-tray capacity, allowing for the sterilization of a large number of instruments at once. The high-quality ultraviolet light used in the chamber guarantees maximum efficiency in destroying harmful microorganisms, providing peace of mind to medical professionals and practitioners. The Waldent Wal-Cab UV Chamber is an essential tool in maintaining a sterile and safe environment in medical, dental, and laboratory settings. Its advanced technology and enhanced sterilization capabilities make it a reliable and indispensable asset for any facility committed to infection control and patient safety.

     

    Note:  Any kind of physical damage is not included in the warranty.

    Key Specifications

    TECHNICAL SPECIFICATIONS:

    UV Cabinet Size (Complete)Dimensions
    Length56cm
    Breadth30cm
    Height20cm
      
    UV Chamber Size 
    Length52cm
    Breadth23cm
    Height15cm
      
    Stainless Steel Tray (Autoclavable) 
    Length24cm
    Breadth15cm
    Depth1.5cm
    ColoursPearl White, Walnut Brown

     

    Compatible UV Chamber Trays:

    Packaging

    1 UV Chamber including:

    • 1 x UV Light Tube
    • 12 x Stainless Steel (Autoclavable Trays)

    Direction to Use

    Preparation:

    • Ensure the UV chamber is placed on a stable and level surface in a clean environment free from dust and debris.
    • Verify that the chamber is connected to a reliable power supply.
    • Make sure the UV chamber is clean and free from any residues from previous use.

    Safety Precautions:

    • Always wear appropriate personal protective equipment (PPE) such as gloves and safety glasses while handling instruments.
    • Avoid direct exposure of eyes and skin to UV light during operation.

    Switch on the Main Power Supply:

    • Turn on the main power supply of the UV chamber to activate the UVGI technology. The power indicator should light up, indicating that the chamber is powered on.

    Open the Door:

    • Gently open the door of the UV chamber. Avoid swinging it open too forcefully to prevent any damage.

    Prepare Instruments:

    • Place the sterilized instruments inside the stainless steel autoclavable trays, ensuring they are arranged in a way that allows proper exposure to the UV light.

    Load the Chamber:

    • Carefully place the stainless steel trays with the instruments inside the UV chamber. Make sure the trays do not touch each other or block the UV light’s path.

    Close the Door:

    • Once the instruments are loaded, securely close the door of the UV chamber. Ensure it is tightly sealed to allow for effective sterilization.

    Start the Sterilization Cycle:

    • Activate the UV sterilization cycle. The duration of the cycle may vary based on the manufacturer’s recommendations and the specific requirements of the instruments being sterilized.

    Monitor the Cycle:

    • While the sterilization cycle is in progress, monitor the process to ensure everything is functioning correctly.

    Completing the Sterilization:

    • Once the sterilization cycle is complete, the UV chamber may have an indicator or signal to notify you. Wait for the cycle to finish before opening the door.

    Safety First:

    • Before opening the door, make sure to switch off the UV chamber to avoid direct exposure to UV light.

    Remove Sterilized Instruments:

    • After the cycle is complete and the UV chamber is safe to open, remove the sterilized instruments using proper techniques and handling procedures.

    1. We offer Worldwide Shipping by Courier via Air or Sea mode.
    2. Product will be dispatched within 5-7 working days.
    3. Delivery will take a maximum of 7-15 days, based on the shipping option you choose.
    4. Kindly check customs restrictions and rules in your country for specific products, mostly 99% shipments are cleared and delivered smoothly.
    5. For Bulk inquiries or customized manufacturing please contact us.

    Product Enquiry

    Categories
    My Cart
    Wishlist
    Recently Viewed
    Categories
    Click to Chat!
    Scan the code
    GEE - I have a question about Waldent Wal-Cab UV Chamber 12 Trays - https://gloriaexports.com/product/waldent-wal-cab-uv-chamber-12-trays/